Your success is our mission; look us over and see why we're the Right Choice for all your contracting needs.Your success is our mission; look us over and see why we're the Right Choice for all your contracting needs.
FIRE PROTECTION SYSTEM

EPC INDIA is also focused on Fire Protection Engineering and Technology. The company has engaged in design, execution and commissioning of various Fire Protection systems.

Our sound infrastructure has enabled us to design and install superior quality fire protection and passive fire protection equipment. The entire gamut is fabricated with qualitative material such as steel, nitrogen gas, carbon di oxide gas and others. All the material is procured from reliable vendors after proper testing to ensure that products offer reliable performance.

PRODUCT & SERVICES

  • Fire Hydrant Wet Riser Systems
  • Down Comer Systems 
  • Automatic Fire Alarm & Smoke Detectors 
  • Automatic Sprinkler Systems 
  • Medium Velocity Water Spray Systems

Fire Hydrant Wet Riser

Atomobile

Wet risers are a form of internal hydrant for the fireman to use and are always pressurized with water. Wet risers are only required for buildings where the topmost floor is higher than 30.5 meters above the fire appliance access level.

Wet riser system comprises duty fire pump with standby pump discharging into a 150mm diameter riser pipe with landing valves at each floor and to which canvas hose with nozzles cab be connected to direct the water jet at the fire. A jockey pump is usually provided to maintain system pressure. For high rise buildings, each stage of the wet riser should not exceed 70.15 meters.

Down Comer System

Atomobile

Down comers are also a form of internal hydrant for the firemen to use and are always charged with water tank located at the top of a building but without any pumps. Down comers are only permitted for private residential buildings with open balcony approach where the topmost floor is not higher than 60 meters above the fire appliance access level and should be adopted for low cost flats only.

Down comers system comprises a high level water storage tank discharging into 150mm diameter riser pipe with landing valves at each floor and to which canvas hose with nozzles can be connected to direct the water jet at the fire. No pumps are provided and therefore the system pressure is limited to the static pressure only.

Automatic Fire Alarm & Smoke Detection System

Atomobile

Fire detection and alarm systems are designed to provide warning of the outbreak of fire and allow appropriate fire fighting action to be taken before the situation gets out of control. As all systems are designed primarily to protect life, property, this places a great responsibility on the designer because each building will present a different set of problems in relation to the risk of fire and fire spread.Each fire detection and alarm system therefore must be specially designed to meet the requirements for each building.

The fire alarm system can either be operated automatically or manually. Automatic operation is via the detectors whereas manual operation is by breaking the glass at the manual call point (break glass unit).

Automatic Sprinkler System

Atomobile

Sprinklers fixed on pipe work charged with water spaced at regular intervals installed throughout the protected building and are connected to a reliable water supply. When a fire occurs, only the sprinklers in the immediate vicinity of the fire automatically operate the discharged water to control the fire. Sprinklers are not so sensitive that they operate at a stage when prompt manual first aid operations still have a chance of success.

These factors limit the damage to very low proportions. The operation of any one sprinkler causes an alarm to sound to bring help to the scene so that the water may be shut off as soon as the fire has been extinguished.

Medium Velocity Water Spray System

Atomobile

Medium Velocity Water Spray Nozzles has an external deflector, which discharges water in a directional cone shaped pattern of small droplet size. The water is uniformly distributed over the surface to be protected. The nozzle is used in deluge water spray system for special hazard fire protection application. As the design and intent of specific water spray system may vary considerably, a MV nozzle is made available in several combination of orifice sizes and spray angles.

Some of the areas where this system is widely used are:
  • Horizontal storage vessels (like LPG Bullets, NH3 storage tanks etc.)
  • Vertical storage vessels (like benzene, xylene, toluene tank age etc.)
  • Spherical storage vessels (like LPG bullets, spheres etc.)
  • Spot protection (Protection of selective areas/ equipments)
I want to Know More
Testominal